home βΊ Package libnvme-devel
Package libnvme-devel
nbft_control(2) β NBFT Table - Control Descriptor (Figure 8)
nbft_control_flags(2) β Control Descriptor Flags
nbft_desc_type(2) β NBFT Elements - Descriptor Types (Figure 5)
nbft_discovery(2) β Discovery Descriptor (Figure 24)
nbft_discovery_flags(2) β Discovery Descriptor Flags
nbft_header(2) β NBFT Table - Header (Figure 8)
nbft_heap_obj(2) β NBFT Header Driver Signature
nbft_hfi(2) β Host Fabric Interface (HFI) Descriptor (Figure 11)
nbft_hfi_flags(2) β HFI Descriptor Flags
nbft_hfi_info_tcp(2) β HFI Transport Info Descriptor - NVMe/TCP (Figure 13)
nbft_hfi_info_tcp_flags(2) β HFI Transport Flags
nbft_host(2) β Host Descriptor (Figure 9)
nbft_host_flags(2) β Host Flags
nbft_info(2) β The parsed NBFT table data.
nbft_info_discovery(2) β Discovery Descriptor
nbft_info_hfi(2) β Host Fabric Interface (HFI) Descriptor
nbft_info_hfi_info_tcp(2) β HFI Transport Info Descriptor - NVMe/TCP
nbft_info_host(2) β Host Descriptor
nbft_info_nid_type(2) β Namespace Identifier Type (NIDT)
nbft_info_primary_admin_host_flag(2) β Primary Administrative Host Descriptor Flags
nbft_info_security(2) β Security Profile Descriptor
nbft_info_subsystem_ns(2) β Subsystem Namespace (SSNS) info
nbft_security(2) β Security Profile Descriptor (Figure 21)
nbft_security_flags(2) β Security Profile Descriptor Flags (Figure 22)
nbft_security_secret_type(2) β Security Profile Descriptor Secret Type
nbft_ssns(2) β Subsystem Namespace (SSNS) Descriptor (Figure 15)
nbft_ssns_ext_info(2) β Subsystem and Namespace Extended Information Descriptor (Figure 19)
nbft_ssns_ext_info_flags(2) β Subsystem and Namespace Extended Information Descriptor Flags
nbft_ssns_flags(2) β Subsystem and Namespace Specific Flags Field (Figure 16)
nbft_ssns_trflags(2) β SSNS Transport Specific Flags Field (Figure 17)
nbft_trtype(2) β NBFT Interface Transport Types (Figure 7)
nvme_acq(2) β This field indicates the admin completion queue base address
nvme_admin_opcode(2) β Known NVMe admin opcodes
nvme_admin_passthru(2) β Submit an nvme passthrough command
nvme_admin_passthru64(2) β Submit a 64-bit nvme passthrough command
nvme_ae_info_css_nvm(2) β Asynchronous Event Information - I/O Command Specific Status
nvme_ae_info_error(2) β Asynchronous Event Information - Error Status
nvme_ae_info_notice(2) β Asynchronous Event Information - Notice
nvme_ae_info_smart(2) β Asynchronous Event Information - SMART / Health Status
nvme_ae_type(2) β Asynchronous Event Type
nvme_aggregate_endurance_group_event(2) β Endurance Group Event Aggregate
nvme_aggregate_predictable_lat_event(2) β Predictable Latency Event Aggregate Log Page
nvme_ana_group_desc(2) β ANA Group Descriptor
nvme_ana_log(2) β Asymmetric Namespace Access Log
nvme_ana_state(2) β ANA Group Descriptor - Asymmetric Namespace Access State
nvme_apst_entry(2) β Autonomous Power State Transition
nvme_aqa(2) β This field indicates the admin queue attributes
nvme_asq(2) β This field indicates the admin submission queue base address
nvme_ave_discover_log(2) β AVE Discovery Log
nvme_ave_discover_log_entry(2) β AVE Discovery Log Entry
nvme_ave_tr_record(2) β AVE Transport Record
nvme_boot_partition(2) β Boot Partition Log
nvme_boot_partition_info(2) β This field indicates the boot partition information
nvme_bpinfo(2) β This field indicates the boot partition information
nvme_bpmbl(2) β This field indicates the boot partition memory buffer location
nvme_bprsel(2) β This field indicates the boot partition read select
nvme_cap(2) β This field indicates the controller capabilities register
nvme_capacity_config_desc(2) β Capacity Configuration structure definitions
nvme_capacity_mgmt(2) β Capacity management command
nvme_capacity_mgmt_args(2) β Arguments for the NVMe Capacity Management command
nvme_cc(2) β This field indicates the controller configuration
nvme_change_ns_event(2) β Change Namespace Event Data
nvme_channel_config_desc(2) β Channel Configuration Descriptor
nvme_clear_etdas(2) β Clear the Extended Telemetry Data Area 4 Supported bit
nvme_cmb_size(2) β Calculate size of the controller memory buffer
nvme_cmbebs(2) β This field indicates the controller memory buffer elasticity buffer size
nvme_cmbloc(2) β This field indicates the controller memory buffer location
nvme_cmbmsc(2) β This field indicates the controller memory buffer memory space control
nvme_cmbsts(2) β This field indicates the controller memory buffer status
nvme_cmbswtp(2) β This field indicates the controller memory buffer sustained write throughput
nvme_cmbsz(2) β This field indicates the controller memory buffer size
nvme_cmd_effects(2) β Commands Supported and Effects
nvme_cmd_effects_log(2) β Commands Supported and Effects Log
nvme_cmd_format_mset(2) β Format NVM - Metadata Settings
nvme_cmd_format_pi(2) β Format NVM - Protection Information
nvme_cmd_format_pil(2) β Format NVM - Protection Information Location
nvme_cmd_format_ses(2) β Format NVM - Secure Erase Settings
nvme_cmd_get_log_lid(2) β Get Log Page -Log Page Identifiers
nvme_cmd_get_log_telemetry_host_lsp(2) β Telemetry Host-Initiated log specific field
nvme_cmic(2) β This field indicates the controller multi-path I/O and NS sharing capabilities
nvme_compare(2) β Submit an nvme user compare command
nvme_connect_err(2) β nvme connect error codes
nvme_constants(2) β A place to stash various constant nvme values
nvme_copy(2) β Copy command
nvme_copy_args(2) β Arguments for the NVMe Copy command
nvme_copy_range(2) β Copy - Source Range Entries Descriptor Format
nvme_copy_range_f1(2) β Copy - Source Range Entries Descriptor Format 1h
nvme_copy_range_f2(2) β Copy - Source Range Entries Descriptor Format 2h
nvme_copy_range_f3(2) β Copy - Source Range Entries Descriptor Format 3h
nvme_copy_range_sopt(2) β NVMe Copy Range Source Options
nvme_create_ctrl(2) β Allocate an unconnected NVMe controller
nvme_create_root(2) β Initialize root object
nvme_crto(2) β This field indicates the controller ready timeouts
nvme_csi(2) β Defined command set indicators
nvme_csts(2) β This field indicates the controller status register
nvme_ctrl_config_match(2) β Check if ctrl @c matches config params
nvme_ctrl_find(2) β Locate an existing controller
nvme_ctrl_first_ns(2) β Start namespace iterator
nvme_ctrl_first_path(2) β Start path iterator
nvme_ctrl_for_each_ns(2) β Traverse namespaces
nvme_ctrl_for_each_ns_safe(2) β Traverse namespaces
nvme_ctrl_for_each_path(2) β Traverse paths
nvme_ctrl_for_each_path_safe(2) β Traverse paths
nvme_ctrl_get_address(2) β Address string of a controller
nvme_ctrl_get_config(2) β Fabrics configuration of a controller
nvme_ctrl_get_dhchap_host_key(2) β Return host key
nvme_ctrl_get_dhchap_key(2) β Return controller key
nvme_ctrl_get_fd(2) β Get associated file descriptor
nvme_ctrl_get_firmware(2) β Firmware string of a controller
nvme_ctrl_get_host_iface(2) β Host interface name of a controller
nvme_ctrl_get_host_traddr(2) β Host transport address of a controller
nvme_ctrl_get_keyring(2) β Return keyring
nvme_ctrl_get_model(2) β Model of a controller
nvme_ctrl_get_name(2) β sysfs name of a controller
nvme_ctrl_get_numa_node(2) β NUMA node of a controller
nvme_ctrl_get_phy_slot(2) β PCI physical slot number of a controller
nvme_ctrl_get_queue_count(2) β Queue count of a controller
nvme_ctrl_get_serial(2) β Serial number of a controller
nvme_ctrl_get_sqsize(2) β SQ size of a controller
nvme_ctrl_get_src_addr(2) β Extract src_addr from the c->address string
nvme_ctrl_get_state(2) β Running state of a controller
nvme_ctrl_get_subsysnqn(2) β Subsystem NQN of a controller
nvme_ctrl_get_subsystem(2) β Parent subsystem of a controller
nvme_ctrl_get_sysfs_dir(2) β sysfs directory of a controller
nvme_ctrl_get_tls_key(2) β Return Derive TLS PSK
nvme_ctrl_get_tls_key_identity(2) β Return Derive TLS Identity
nvme_ctrl_get_traddr(2) β Transport address of a controller
nvme_ctrl_get_transport(2) β Transport type of a controller
nvme_ctrl_get_trsvcid(2) β Transport service identifier of a controller
nvme_ctrl_identify(2) β Issues an 'identify controller' command
nvme_ctrl_is_discovered(2) β Returns the value of the 'discovered' flag
nvme_ctrl_is_discovery_ctrl(2) β Check the 'discovery_ctrl' flag
nvme_ctrl_is_persistent(2) β Returns the value of the 'persistent' flag
nvme_ctrl_is_unique_discovery_ctrl(2) β Check the 'unique_discovery_ctrl' flag
nvme_ctrl_list(2) β Controller List
nvme_ctrl_metadata_type(2) β Controller Metadata Element Types
nvme_ctrl_next_ns(2) β Next namespace iterator
nvme_ctrl_next_path(2) β Next path iterator
nvme_ctrl_release_fd(2) β Close fd and clear fd from controller object
nvme_ctrl_reset(2) β Initiate a controller reset
nvme_ctrl_set_dhchap_host_key(2) β Set host key
nvme_ctrl_set_dhchap_key(2) β Set controller key
nvme_ctrl_set_discovered(2) β Set the 'discovered' flag
nvme_ctrl_set_discovery_ctrl(2) β Set the 'discovery_ctrl' flag
nvme_ctrl_set_keyring(2) β Set keyring
nvme_ctrl_set_persistent(2) β Set the 'persistent' flag
nvme_ctrl_set_tls_key(2) β Set Derive TLS PSK
nvme_ctrl_set_tls_key_identity(2) β Set Derive TLS Identity
nvme_ctrl_set_unique_discovery_ctrl(2) β Set the 'unique_discovery_ctrl' flag
nvme_ctrls_filter(2) β Filter for controllers
nvme_data_tfr(2) β Data transfer direction of the command
nvme_default_host(2) β Initializes the default host
nvme_describe_key_serial(2) β Return key description
nvme_dev_self_test(2) β Start or abort a self test
nvme_dev_self_test_args(2) β Arguments for the NVMe Device Self Test command
nvme_dim_args(2) β Arguments for the Discovery Information Management (DIM) command
nvme_directive_dtype(2) β Directive Types
nvme_directive_receive_doper(2) β Directive Receive Directive Operation
nvme_directive_recv(2) β Receive directive specific data
nvme_directive_recv_args(2) β Arguments for the NVMe Directive Receive command
nvme_directive_recv_identify_parameters(2) β Directive receive identifier parameters
nvme_directive_recv_stream_allocate(2) β Directive receive stream allocate
nvme_directive_recv_stream_parameters(2) β Directive receive stream parameters
nvme_directive_recv_stream_status(2) β Directive receive stream status
nvme_directive_send(2) β Send directive command
nvme_directive_send_args(2) β Arguments for the NVMe Directive Send command
nvme_directive_send_doper(2) β Directive Send Directive Operation
nvme_directive_send_id_endir(2) β Directive Send Enable Directive
nvme_directive_send_identify_endir(2) β Enable Directive
nvme_directive_send_stream_release_identifier(2) β Directive Send Stream release
nvme_directive_send_stream_release_resource(2) β Directive Send Stream release resources
nvme_directive_types(2) β Directives Supported or Enabled
nvme_disconnect_ctrl(2) β Disconnect a controller
nvme_dispersed_ns_participating_nss_log(2) β Dispersed Namespace Participating NVM Subsystems Log
nvme_dsm(2) β Send an nvme data set management command
nvme_dsm_args(2) β Arguments for the NVMe Dataset Management command
nvme_dsm_attributes(2) β Dataset Management attributes
nvme_dsm_range(2) β Dataset Management - Range Definition
nvme_dst_stc(2) β Action taken by the Device Self-test command
nvme_dump_config(2) β Print the JSON configuration
nvme_dump_tree(2) β Dump internal object tree
nvme_eg_critical_warning_flags(2) β Endurance Group Information Log - Critical Warning
nvme_eg_event_aggregate_log(2) β Endurance Group Event Aggregate
nvme_end_grp_chan_desc(2) β Endurance Group Channel Configuration Descriptor
nvme_end_grp_config_desc(2) β Endurance Group Configuration Descriptor
nvme_endurance_group_log(2) β Endurance Group Information Log
nvme_eom_lane_desc(2) β EOM Lane Descriptor
nvme_eom_optional_data(2) β EOM Optional Data Present Fields (Deprecated)
nvme_eom_optional_data_present(2) β EOM Optional Data Present Fields
nvme_err_status_field(2) β This field indicates the error information log entry status field
nvme_errno_to_string(2) β Returns string describing nvme connect failures
nvme_error_log_page(2) β Error Information Log Entry (Log Identifier 01h)
nvme_export_tls_key(2) β Export a TLS key
nvme_export_tls_key_versioned(2) β Export a TLS pre-shared key
nvme_fabrics_config(2) β Defines all linux nvme fabrics initiator options
nvme_fabrics_uri(2) β Parsed URI structure
nvme_fctype(2) β Fabrics Command Types
nvme_fdp_config_desc(2) β FDP Configuration Descriptor
nvme_fdp_config_fdpa(2) β FDP Attributes
nvme_fdp_config_log(2) β FDP Configurations Log Page
nvme_fdp_event(2) β FDP Event
nvme_fdp_event_flags(2) β FDP Event Flags
nvme_fdp_event_realloc(2) β Media Reallocated Event Type Specific Information
nvme_fdp_event_realloc_flags(2) β Media Reallocated Event Type Specific Flags
nvme_fdp_event_type(2) β FDP Event Types
nvme_fdp_events_log(2) β FDP Events Log Page
nvme_fdp_reclaim_unit_handle_status(2) β Get reclaim unit handle status
nvme_fdp_reclaim_unit_handle_update(2) β Update a list of reclaim unit handles
nvme_fdp_ruh_desc(2) β Reclaim Unit Handle Descriptor
nvme_fdp_ruh_status(2) β Reclaim Unit Handle Status
nvme_fdp_ruh_status_desc(2) β Reclaim Unit Handle Status Descriptor
nvme_fdp_ruh_type(2) β Reclaim Unit Handle Type
nvme_fdp_ruha(2) β Reclaim Unit Handle Attributes
nvme_fdp_ruhu_desc(2) β Reclaim Unit Handle Usage Descriptor
nvme_fdp_ruhu_log(2) β Reclaim Unit Handle Usage Log Page
nvme_fdp_stats_log(2) β FDP Statistics Log Page
nvme_fdp_supported_event_attributes(2) β Supported FDP Event Attributes
nvme_fdp_supported_event_desc(2) β Supported FDP Event Descriptor
nvme_feat(2) β Features Access Shifts/Masks values
nvme_feat_auto_pst(2) β Autonomous Power State Transition
nvme_feat_bpwp_state(2) β Boot Partition Write Protection State
nvme_feat_fdp_events_cdw11(2) β FDP Events Feature Command Dword 11 Deprecated: doesn't support this struct. Use NVME_FEAT_FDPE_*** definitions instead.
nvme_feat_host_behavior(2) β Host Behavior Support - Data Structure
nvme_feat_nswpcfg_state(2) β Write Protection - Write Protection State
nvme_feat_perfc_attri(2) β performance characteristics attribute index
nvme_feat_perfc_r4karl(2) β standard performance attribute random 4 kib average latency
nvme_feat_plm_window_select(2) β Predictable Latency Per NVM Set Log
nvme_feat_resv_notify_flags(2) β Reservation Notification Configuration
nvme_feat_tmpthresh_thsel(2) β Temperature Threshold - Threshold Type Select
nvme_features_async_event_config_flags(2) β Asynchronous Event Configuration configuration flags
nvme_features_id(2) β Features - Feature Identifiers
nvme_fid_supported_effects(2) β FID Supported and Effects Data Structure definitions
nvme_fid_supported_effects_log(2) β Feature Identifiers Supported and Effects
nvme_firmware_slot(2) β Firmware Slot Information Log
nvme_first_host(2) β Start host iterator
nvme_first_subsystem(2) β Start subsystem iterator
nvme_flbas(2) β This field indicates the formatted LBA size
nvme_flush(2) β Send an nvme flush command
nvme_for_each_host(2) β Traverse host list
nvme_for_each_host_safe(2) β Traverse host list
nvme_for_each_subsystem(2) β Traverse subsystems
nvme_for_each_subsystem_safe(2) β Traverse subsystems
nvme_format_nvm(2) β Format nvme namespace(s)
nvme_format_nvm_args(2) β Arguments for the Format Nvme Namespace command
nvme_format_nvm_compln_event(2) β Format NVM Completion Event Data
nvme_format_nvm_start_event(2) β Format NVM Start Event Data
nvme_free_ctrl(2) β Free controller
nvme_free_host(2) β Free nvme_host_t object
nvme_free_ns(2) β Free a namespace object
nvme_free_subsystem(2) β Free a subsystem
nvme_free_tree(2) β Free root object
nvme_free_uri(2) β Free the URI structure
nvme_fw_commit(2) β Commit firmware using the specified action
nvme_fw_commit_args(2) β Arguments for the NVMe Firmware Commit command
nvme_fw_commit_ca(2) β Firmware Commit - Commit Action
nvme_fw_commit_event(2) β Firmware Commit Event Data
nvme_fw_download(2) β Download part or all of a firmware image to the controller
nvme_fw_download_args(2) β Arguments for the NVMe Firmware Download command
nvme_fw_download_seq(2) β Firmware download sequence
nvme_gen_dhchap_key(2) β DH-HMAC-CHAP key generation
nvme_generate_tls_key_identity(2) β Generate the TLS key identity
nvme_generate_tls_key_identity_compat(2) β Generate the TLS key identity
nvme_get_ana_log_atomic(2) β Retrieve Asymmetric Namespace Access log page atomically
nvme_get_ana_log_len(2) β Retrieve size of the current ANA log
nvme_get_ana_log_len_from_id_ctrl(2) β Retrieve maximum possible ANA log size
nvme_get_attr(2) β Read sysfs attribute
nvme_get_ctrl_attr(2) β Read controller sysfs attribute
nvme_get_ctrl_telemetry(2) β Get controller telemetry log
nvme_get_directive_receive_length(2) β Get directive receive length
nvme_get_discovery_args(2) β Arguments for nvmf_get_discovery_wargs()
nvme_get_feature_length(2) β Retreive the command payload length for a specific feature identifier
nvme_get_feature_length2(2) β Retreive the command payload length for a specific feature identifier
nvme_get_features(2) β Retrieve a feature attribute
nvme_get_features_arbitration(2) β Get arbitration feature
nvme_get_features_args(2) β Arguments for the NVMe Admin Get Feature command
nvme_get_features_async_event(2) β Get asynchronous event feature
nvme_get_features_auto_pst(2) β Get autonomous power state feature
nvme_get_features_data(2) β Helper function for @nvme_get_features()
nvme_get_features_endurance_event_cfg(2) β Get endurance event config feature
nvme_get_features_err_recovery(2) β Get error recovery feature
nvme_get_features_err_recovery2(2) β Get error recovery feature
nvme_get_features_hctm(2) β Get thermal management feature
nvme_get_features_host_behavior(2) β Get host behavior feature
nvme_get_features_host_id(2) β Get host id feature
nvme_get_features_host_mem_buf(2) β Get host memory buffer feature
nvme_get_features_host_mem_buf2(2) β Get host memory buffer feature
nvme_get_features_iocs_profile(2) β Get IOCS profile feature
nvme_get_features_irq_coalesce(2) β Get IRQ coalesce feature
nvme_get_features_irq_config(2) β Get IRQ config feature
nvme_get_features_kato(2) β Get keep alive timeout feature
nvme_get_features_lba_range(2) β Get LBA range feature
nvme_get_features_lba_range2(2) β Get LBA range feature
nvme_get_features_lba_sts_interval(2) β Get LBA status information feature
nvme_get_features_nopsc(2) β Get non-operational power state feature
nvme_get_features_num_queues(2) β Get number of queues feature
nvme_get_features_plm_config(2) β Get predictable latency feature
nvme_get_features_plm_window(2) β Get window select feature
nvme_get_features_power_mgmt(2) β Get power management feature
nvme_get_features_resv_mask(2) β Get reservation mask feature
nvme_get_features_resv_mask2(2) β Get reservation mask feature
nvme_get_features_resv_persist(2) β Get reservation persist feature
nvme_get_features_resv_persist2(2) β Get reservation persist feature
nvme_get_features_rrl(2) β Get read recovery level feature
nvme_get_features_sanitize(2) β Get sanitize feature
nvme_get_features_sel(2) β Get Features - Select
nvme_get_features_simple(2) β Helper function for @nvme_get_features()
nvme_get_features_sw_progress(2) β Get software progress feature
nvme_get_features_temp_thresh(2) β Get temperature threshold feature
nvme_get_features_temp_thresh2(2) β Get temperature threshold feature
nvme_get_features_timestamp(2) β Get timestamp feature
nvme_get_features_volatile_wc(2) β Get volatile write cache feature
nvme_get_features_write_atomic(2) β Get write atomic feature
nvme_get_features_write_protect(2) β Get write protect feature
nvme_get_host_telemetry(2) β Get host telemetry log
nvme_get_lba_status(2) β Retrieve information on possibly unrecoverable LBAs
nvme_get_lba_status_args(2) β Arguments for the NVMe Get LBA Status command
nvme_get_lba_status_log(2) β Retrieve the LBA Status log page
nvme_get_log(2) β NVMe Admin Get Log command
nvme_get_log_ana(2) β Retrieve Asymmetric Namespace Access log page
nvme_get_log_ana_groups(2) β Retrieve Asymmetric Namespace Access groups only log page
nvme_get_log_args(2) β Arguments for the NVMe Admin Get Log command
nvme_get_log_ave_discover(2) β Retrieve AVE Discovery Log
nvme_get_log_boot_partition(2) β Retrieve Boot Partition
nvme_get_log_changed_alloc_ns_list(2) β Retrieve Changed Allocated Namespace List Log
nvme_get_log_changed_ns_list(2) β Retrieve namespace changed list
nvme_get_log_cmd_effects(2) β Retrieve nvme command effects log
nvme_get_log_create_telemetry_host(2) β Create host telemetry log
nvme_get_log_create_telemetry_host_mcda(2) β Create host telemetry log
nvme_get_log_device_self_test(2) β Retrieve the device self test log
nvme_get_log_discovery(2) β Retrieve Discovery log page
nvme_get_log_dispersed_ns_participating_nss(2) β Retrieve Dispersed Namespace Participating NVM Subsystems Log
nvme_get_log_endurance_group(2) β Get Endurance Group log
nvme_get_log_endurance_grp_evt(2) β Retrieve Endurance Group Event Aggregate
nvme_get_log_error(2) β Retrieve nvme error log
nvme_get_log_fdp_configurations(2) β Get list of Flexible Data Placement configurations
nvme_get_log_fdp_events(2) β Get Flexible Data Placement events
nvme_get_log_fdp_stats(2) β Get Flexible Data Placement statistics
nvme_get_log_fid_supported_effects(2) β Retrieve Feature Identifiers Supported and Effects
nvme_get_log_fw_slot(2) β Retrieves the controller firmware log
nvme_get_log_host_discover(2) β Retrieve Host Discovery Log
nvme_get_log_lba_status(2) β Retrieve LBA Status
nvme_get_log_lockdown(2) β Retrieve lockdown Log
nvme_get_log_media_unit_stat(2) β Retrieve Media Unit Status
nvme_get_log_mgmt_addr_list(2) β Retrieve Management Address List Log
nvme_get_log_mi_cmd_supported_effects(2) β displays the MI Commands Supported by the controller
nvme_get_log_page(2) β Get log page data
nvme_get_log_persistent_event(2) β Retrieve Persistent Event Log
nvme_get_log_phy_rx_eom(2) β Retrieve Physical Interface Receiver Eye Opening Measurement Log
nvme_get_log_predictable_lat_event(2) β Retrieve Predictable Latency Event Aggregate Log Page
nvme_get_log_predictable_lat_nvmset(2) β Predictable Latency Per NVM Set
nvme_get_log_pull_model_ddc_req(2) β Retrieve Pull Model DDC Request Log
nvme_get_log_reachability_associations(2) β Retrieve Reachability Associations Log
nvme_get_log_reachability_groups(2) β Retrieve Reachability Groups Log
nvme_get_log_reclaim_unit_handle_usage(2) β Get reclaim unit handle usage
nvme_get_log_reservation(2) β Retrieve Reservation Notification
nvme_get_log_rotational_media_info(2) β Retrieve Rotational Media Information Log
nvme_get_log_sanitize(2) β Retrieve Sanitize Status
nvme_get_log_smart(2) β Retrieve nvme smart log
nvme_get_log_support_cap_config_list(2) β Retrieve Supported Capacity Configuration List
nvme_get_log_supported_log_pages(2) β Retrieve nmve supported log pages
nvme_get_log_telemetry_ctrl(2) β Get Telemetry Controller-Initiated log page
nvme_get_log_telemetry_host(2) β Get Telemetry Host-Initiated log page
nvme_get_log_zns_changed_zones(2) β Retrieve list of zones that have changed
nvme_get_logging_level(2) β Get current logging level
nvme_get_logical_block_size(2) β Retrieve block size
nvme_get_new_host_telemetry(2) β Get new host telemetry log
nvme_get_ns_attr(2) β Read namespace sysfs attribute
nvme_get_nsid(2) β Retrieve the NSID from a namespace file descriptor
nvme_get_path_attr(2) β Read path sysfs attribute
nvme_get_property(2) β Get a controller property
nvme_get_property_args(2) β Arguments for NVMe Get Property command
nvme_get_subsys_attr(2) β Read subsystem sysfs attribute
nvme_get_telemetry_log(2) β Get specified telemetry log
nvme_get_telemetry_max(2) β Get telemetry limits
nvme_hmac_alg(2) β HMAC algorithm
nvme_host_behavior_support(2) β Enable Advanced Command
nvme_host_discover_log(2) β Host Discovery Log
nvme_host_ext_discover_log(2) β Host Extended Discovery Log
nvme_host_get_dhchap_key(2) β Return host key
nvme_host_get_hostid(2) β Host ID of an nvme_host_t object
nvme_host_get_hostnqn(2) β Host NQN of an nvme_host_t object
nvme_host_get_hostsymname(2) β Get the host's symbolic name
nvme_host_get_root(2) β Returns nvme_root_t object
nvme_host_is_pdc_enabled(2) β Is Persistenct Discovery Controller enabled
nvme_host_mem_buf_attrs(2) β Host Memory Buffer - Attributes Data Structure
nvme_host_metadata(2) β Host Metadata Data Structure
nvme_host_release_fds(2) β Close all opened file descriptors under host
nvme_host_set_dhchap_key(2) β set host key
nvme_host_set_hostsymname(2) β Set the host's symbolic name
nvme_host_set_pdc_enabled(2) β Set Persistent Discovery Controller flag
nvme_id_ctrl(2) β Identify Controller data structure
nvme_id_ctrl_anacap(2) β This field indicates the capabilities associated with Asymmetric Namespace Access Reporting.
nvme_id_ctrl_apsta(2) β Flags indicating the attributes of the autonomous power state transition feature.
nvme_id_ctrl_avscc(2) β Flags indicating the configuration settings for Admin Vendor Specific command handling.
nvme_id_ctrl_bpcap(2) β Boot Partition Capabilities
nvme_id_ctrl_cmic(2) β Controller Multipath IO and Namespace Sharing Capabilities of the controller and NVM subsystem.
nvme_id_ctrl_cntrltype(2) β Controller types
nvme_id_ctrl_cqes(2) β Defines the required and maximum Completion Queue entry size when using the NVM Command Set.
nvme_id_ctrl_crcap(2) β Power Loss Signaling Information
nvme_id_ctrl_ctratt(2) β Controller attributes
nvme_id_ctrl_dctype(2) β Discovery Controller types
nvme_id_ctrl_dsto(2) β Flags indicating the optional Device Self-test command or operation behaviors supported by the controller or NVM subsystem.
nvme_id_ctrl_fcatt(2) β This field indicates attributes of the controller that are specific to NVMe over Fabrics.
nvme_id_ctrl_fna(2) β This field indicates attributes for the Format NVM command.
nvme_id_ctrl_frmw(2) β Flags and values indicates capabilities regarding firmware updates from &struct nvme_id_ctrl.frmw.
nvme_id_ctrl_fuses(2) β This field indicates the fused operations that the controller supports.
nvme_id_ctrl_hctm(2) β Flags indicate the attributes of the host controlled thermal management feature
nvme_id_ctrl_kpioc(2) β Key Per I/O Capabilities
nvme_id_ctrl_lpa(2) β Flags indicating optional attributes for log pages that are accessed via the Get Log Page command.
nvme_id_ctrl_mec(2) β Flags indicating the capabilities of the Management Endpoint in the Controller, &struct nvme_id_ctrl.mec.
nvme_id_ctrl_nvm(2) β I/O Command Set Specific Identify Controller data structure
nvme_id_ctrl_nvm_lbamqf(2) β LBA Migration Queue Format
nvme_id_ctrl_nvmsr(2) β This field reports information associated with the NVM Subsystem, see &struct nvme_id_ctrl.nvmsr.
nvme_id_ctrl_nvscc(2) β This field indicates the configuration settings for NVM Vendor Specific command handling.
nvme_id_ctrl_nwpc(2) β This field indicates the optional namespace write protection capabilities supported by the controller.
nvme_id_ctrl_oacs(2) β Flags indicating the optional Admin commands and features supported by the controller, see &struct nvme_id_ctrl.oacs.
nvme_id_ctrl_oaes(2) β Optional Asynchronous Events Supported
nvme_id_ctrl_ofcs(2) β Indicate whether the controller supports optional fabric commands.
nvme_id_ctrl_oncs(2) β This field indicates the optional NVM commands and features supported by the controller.
nvme_id_ctrl_plsi(2) β Power Loss Signaling Information
nvme_id_ctrl_rpmbs(2) β This field indicates if the controller supports one or more Replay Protected Memory Blocks, from &struct nvme_id_ctrl.rpmbs.
nvme_id_ctrl_sanicap(2) β Indicates attributes for sanitize operations.
nvme_id_ctrl_sgls(2) β This field indicates if SGLs are supported for the NVM Command Set and the particular SGL types supported.
nvme_id_ctrl_sqes(2) β Defines the required and maximum Submission Queue entry size when using the NVM Command Set.
nvme_id_ctrl_trattr(2) β Tracking Attributes
nvme_id_ctrl_vwc(2) β Volatile write cache
nvme_id_ctrl_vwci(2) β This field indicates information about remaining number of times that VPD contents are able to be updated using the VPD Write command, see &struct nvme_id_ctrl.vwci.
nvme_id_directives(2) β Identify Directive - Return Parameters Data Structure
nvme_id_domain_attr(2) β Domain Attributes Entry
nvme_id_domain_list(2) β Domain List
nvme_id_endurance_group_list(2) β Endurance Group List
nvme_id_independent_id_ns(2) β Identify - I/O Command Set Independent Identify Namespace Data Structure
nvme_id_iocs(2) β NVMe Identify IO Command Set data structure
nvme_id_iocs_iocsc(2) β This field indicates the Identify I/O Command Set Data Structure
nvme_id_ns(2) β Identify Namespace data structure
nvme_id_ns_attr(2) β Specifies attributes of the namespace.
nvme_id_ns_dlfeat(2) β This field indicates information about features that affect deallocating logical blocks for this namespace.
nvme_id_ns_dpc(2) β This field indicates the capabilities for the end-to-end data protection feature.
nvme_id_ns_dps(2) β This field indicates the Type settings for the end-to-end data protection feature.
nvme_id_ns_flbas(2) β This field indicates the LBA data size & metadata size combination that the namespace has been formatted with
nvme_id_ns_granularity_desc(2) β Namespace Granularity Descriptor
nvme_id_ns_granularity_list(2) β Namespace Granularity List
nvme_id_ns_mc(2) β This field indicates the capabilities for metadata.
nvme_id_ns_nmic(2) β This field specifies multi-path I/O and namespace sharing capabilities of the namespace.
nvme_id_ns_rescap(2) β This field indicates the reservation capabilities of the namespace.
nvme_id_nsfeat(2) β This field defines features of the namespace.
nvme_id_nvmset_list(2) β NVM set list
nvme_id_psd(2) β Power Management data structure
nvme_id_uuid(2) β Identifier Association
nvme_id_uuid_list(2) β UUID list
nvme_id_uuid_list_entry(2) β UUID List Entry
nvme_identify(2) β Send the NVMe Identify command
nvme_identify_active_ns_list(2) β Retrieves active namespaces id list
nvme_identify_active_ns_list_csi(2) β Active namespace ID list associated with a specified I/O command set
nvme_identify_allocated_ns(2) β Same as nvme_identify_ns, but only for allocated namespaces
nvme_identify_allocated_ns_list(2) β Retrieves allocated namespace id list
nvme_identify_allocated_ns_list_csi(2) β Allocated namespace ID list associated with a specified I/O command set
nvme_identify_args(2) β Arguments for the NVMe Identify command
nvme_identify_cns(2) β Identify - CNS Values
nvme_identify_ctrl(2) β Retrieves nvme identify controller
nvme_identify_ctrl_csi(2) β I/O command set specific Identify Controller data
nvme_identify_ctrl_list(2) β Retrieves identify controller list
nvme_identify_domain_list(2) β Domain list data
nvme_identify_endurance_group_list(2) β Endurance group list data
nvme_identify_independent_identify_ns(2) β I/O command set independent Identify namespace data
nvme_identify_iocs(2) β I/O command set data structure
nvme_identify_iocs_ns_csi_user_data_format(2) β Identify I/O command set namespace data structure
nvme_identify_ns(2) β Retrieves nvme identify namespace
nvme_identify_ns_csi(2) β I/O command set specific identify namespace data
nvme_identify_ns_csi_user_data_format(2) β Identify namespace user data format
nvme_identify_ns_descs(2) β Retrieves namespace descriptor list
nvme_identify_ns_granularity(2) β Retrieves namespace granularity identification
nvme_identify_nsid_ctrl_list(2) β Retrieves controller list attached to an nsid
nvme_identify_nvmset_list(2) β Retrieves NVM Set List
nvme_identify_primary_ctrl(2) β Retrieve NVMe Primary Controller identification
nvme_identify_secondary_ctrl_list(2) β Retrieves secondary controller list
nvme_identify_uuid(2) β Retrieves device's UUIDs
nvme_import_tls_key(2) β Import a TLS key
nvme_import_tls_key_versioned(2) β Import a TLS key
nvme_init_copy_range(2) β Constructs a copy range structure
nvme_init_copy_range_f1(2) β Constructs a copy range f1 structure
nvme_init_copy_range_f2(2) β Constructs a copy range f2 structure
nvme_init_copy_range_f3(2) β Constructs a copy range f3 structure
nvme_init_ctrl(2) β Initialize nvme_ctrl_t object for an existing controller.
nvme_init_ctrl_list(2) β Initialize an nvme_ctrl_list structure from an array.
nvme_init_default_logging(2) β Initialize default (fallback) logging
nvme_init_dsm_range(2) β Constructs a data set range structure
nvme_init_logging(2) β Initialize logging
nvme_insert_tls_key(2) β Derive and insert TLS key
nvme_insert_tls_key_compat(2) β Derive and insert TLS key
nvme_insert_tls_key_versioned(2) β Derive and insert TLS key
nvme_io(2) β Submit an nvme user I/O command
nvme_io_args(2) β Arguments for NVMe I/O commands
nvme_io_control_flags(2) β I/O control flags
nvme_io_dsm_flags(2) β Dataset Management flags
nvme_io_mgmt_recv(2) β I/O Management Receive command
nvme_io_mgmt_recv_args(2) β Arguments for the NVMe I/O Management Receive command
nvme_io_mgmt_recv_mo(2) β I/O Management Receive - Management Operation
nvme_io_mgmt_send(2) β I/O Management Send command
nvme_io_mgmt_send_args(2) β Arguments for the NVMe I/O Management Send command
nvme_io_mgmt_send_mo(2) β I/O Management Send - Management Operation
nvme_io_opcode(2) β Opcodes for I/O Commands
nvme_io_passthru(2) β Submit an nvme io passthrough command
nvme_io_passthru64(2) β Submit an nvme io passthrough command
nvme_is_64bit_reg(2) β Checks if offset of the controller register is a know 64bit value.
nvme_kv_opcode(2) β Opcodes for KV Commands
nvme_lba_range_type(2) β LBA Range Type
nvme_lba_range_type_entry(2) β LBA Range Type - Data Structure Entry
nvme_lba_rd(2) β LBA Range Descriptor
nvme_lba_status(2) β LBA Status Descriptor List
nvme_lba_status_atype(2) β Action type the controller uses to return LBA status
nvme_lba_status_cmpc(2) β Get LBA Status Command Completion Condition
nvme_lba_status_desc(2) β LBA Status Descriptor Entry
nvme_lba_status_log(2) β LBA Status Information Log
nvme_lbaf(2) β LBA Format Data Structure
nvme_lbaf_rp(2) β This field indicates the relative performance of the LBA format indicated relative to other LBA formats supported by the controller.
nvme_lbart(2) β LBA Range Type - Data Structure Entry
nvme_lbas_ns_element(2) β LBA Status Log Namespace Element
nvme_lm_cdq(2) β Controller Data Queue - Controller Data Queue command
nvme_lm_cdq_args(2) β Arguments for Controller Data Queue (CDQ) command
nvme_lm_cdq_fields(2) β Controller Data Queue command fields
nvme_lm_controller_state_data(2) β Controller State data structure contains data on the controller's state.
nvme_lm_controller_state_data_header(2) β Controller State data header structure describes the contents of the Controller State data
nvme_lm_ctrl_data_queue_fid(2) β Controller Data Queue - Set Feature
nvme_lm_ctrl_data_queue_fid_data(2) β Get Controller Data Queue feature data
nvme_lm_io_completion_queue_data(2) β I/O Completion Queue data structure. Fields related to the contents of Create I/O Completion Queue command that created an I/O Completion Queue.
nvme_lm_io_submission_queue_data(2) β I/O Submission Queue data structure. Fields related to the contents of Create I/O Submission Queue command that created an I/O Submission Queue.
nvme_lm_migration_recv_args(2) β Arguments for the Migration Receive command
nvme_lm_migration_recv_fields(2) β Migration Receive command fields
nvme_lm_migration_send(2) β Migration Send command
nvme_lm_migration_send_args(2) β Arguments for the Migration Send command
nvme_lm_migration_send_fields(2) β Migration Send command fields
nvme_lm_nvme_controller_state_data(2) β NVMe Controller State data structure describes the state of a NVMe Controller's I/O Submission and I/O Completion queues
nvme_lm_nvme_controller_state_data_header(2) β Controller State data structure header
nvme_lm_queue_attributes(2) β I/O Submission and I/O Completion Queue Attributes
nvme_lm_track_send(2) β Track Send command
nvme_lm_track_send_args(2) β Arguments for the Track Send command
nvme_lm_track_send_fields(2) β Track Send command fields
nvme_lockdown(2) β Issue lockdown command
nvme_lockdown_args(2) β Arguments for the NVME Lockdown command
nvme_lockdown_log(2) β Command and Feature Lockdown Log
nvme_lockdown_log_contents(2) β lockdown log page content attributes
nvme_lockdown_log_scope(2) β lockdown log page scope attributes
nvme_lockdown_scope_contents(2) β Lockdown Log shift and mask
nvme_log_ana_lsp(2) β Asymmetric Namespace Access - Return Groups Only
nvme_log_phy_rx_eom_action(2) β Physical Interface Receiver Eye Opening Measurement Action
nvme_log_phy_rx_eom_quality(2) β Physical Interface Receiver Eye Opening Measurement Quality
nvme_lookup_ctrl(2) β Lookup nvme_ctrl_t object
nvme_lookup_host(2) β Lookup nvme_host_t object
nvme_lookup_key(2) β Lookup key serial number
nvme_lookup_keyring(2) β Lookup keyring serial number
nvme_lookup_subsystem(2) β Lookup nvme_subsystem_t object
nvme_media_unit_config_desc(2) β Media Unit Configuration Descriptor
nvme_media_unit_stat_desc(2) β Media Unit Status Descriptor
nvme_media_unit_stat_log(2) β Media Unit Status
nvme_metadata_element_desc(2) β Metadata Element Descriptor
nvme_mgmt_addr_desc(2) β Management Address Descriptor
nvme_mgmt_addr_list_log(2) β Management Address List Log
nvme_mi_admin_admin_passthru(2) β Submit an nvme admin passthrough command
nvme_mi_admin_format_nvm(2) β Format NVMe namespace
nvme_mi_admin_fw_commit(2) β Commit firmware using the specified action
nvme_mi_admin_fw_download(2) β Download part or all of a firmware image to the controller
nvme_mi_admin_get_ana_log_atomic(2) β Retrieve Asymmetric Namespace Access log page atomically
nvme_mi_admin_get_endgid_log(2) β Helper for Get Endurance Group ID Log Page functions
nvme_mi_admin_get_features_arbitration(2) β Get arbitration feature
nvme_mi_admin_get_features_data(2) β Helper function for &nvme_mi_admin_get_features()
nvme_mi_admin_get_features_power_mgmt(2) β Get power management feature
nvme_mi_admin_get_log(2) β Retrieve log page data from controller
nvme_mi_admin_get_log_ana(2) β Retrieve Asymmetric Namespace Access log page
nvme_mi_admin_get_log_ana_groups(2) β Retrieve Asymmetric Namespace Access groups only log page
nvme_mi_admin_get_log_ave_discover(2) β Retrieve AVE Discovery Log
nvme_mi_admin_get_log_boot_partition(2) β Retrieve Boot Partition
nvme_mi_admin_get_log_changed_alloc_ns_list(2) β Retrieve Changed Allocated Namespace List Log
nvme_mi_admin_get_log_changed_ns_list(2) β Retrieve namespace changed list
nvme_mi_admin_get_log_cmd_effects(2) β Retrieve nvme command effects log
nvme_mi_admin_get_log_create_telemetry_host(2) β Create host telemetry log
nvme_mi_admin_get_log_create_telemetry_host_mcda(2) β Create host telemetry log
nvme_mi_admin_get_log_device_self_test(2) β Retrieve the device self test log
nvme_mi_admin_get_log_discovery(2) β Retrieve Discovery log page
nvme_mi_admin_get_log_dispersed_ns_participating_nss(2) β Retrieve Dispersed Namespace Participating NVM Subsystems Log
nvme_mi_admin_get_log_endurance_group(2) β Get Endurance Group log
nvme_mi_admin_get_log_endurance_grp_evt(2) β Retrieve Rotational Media Information
nvme_mi_admin_get_log_error(2) β Retrieve nvme error log
nvme_mi_admin_get_log_fid_supported_effects(2) β Retrieve Feature Identifiers Supported and Effects
nvme_mi_admin_get_log_fw_slot(2) β Retrieves the controller firmware log
nvme_mi_admin_get_log_host_discover(2) β Retrieve Host Discovery Log
nvme_mi_admin_get_log_lba_status(2) β Retrieve LBA Status
nvme_mi_admin_get_log_lockdown(2) β Retrieve lockdown Log
nvme_mi_admin_get_log_media_unit_stat(2) β Retrieve Media Unit Status
nvme_mi_admin_get_log_mgmt_addr_list(2) β Retrieve Management Address List Log
nvme_mi_admin_get_log_mi_cmd_supported_effects(2) β displays the MI Commands Supported by the controller
nvme_mi_admin_get_log_page(2) β Retrieve log page data from controller
nvme_mi_admin_get_log_persistent_event(2) β Retrieve Persistent Event Log
nvme_mi_admin_get_log_phy_rx_eom(2) β Retrieve Physical Interface Receiver Eye Opening Measurement Log
nvme_mi_admin_get_log_predictable_lat_event(2) β Retrieve Predictable Latency Event Aggregate Log Page
nvme_mi_admin_get_log_predictable_lat_nvmset(2) β Predictable Latency Per NVM Set
nvme_mi_admin_get_log_pull_model_ddc_req(2) β Retrieve Pull Model DDC Request Log
nvme_mi_admin_get_log_reachability_associations(2) β Retrieve Reachability Associations Log
nvme_mi_admin_get_log_reachability_groups(2) β Retrieve Reachability Groups Log
nvme_mi_admin_get_log_reservation(2) β Retrieve Reservation Notification
nvme_mi_admin_get_log_rotational_media_info(2) β Retrieve Rotational Media Information Log
nvme_mi_admin_get_log_sanitize(2) β Retrieve Sanitize Status
nvme_mi_admin_get_log_simple(2) β Helper for Get Log Page functions with no NSID or RAE requirements
nvme_mi_admin_get_log_smart(2) β Retrieve nvme smart log
nvme_mi_admin_get_log_support_cap_config_list(2) β Retrieve Supported Capacity Configuration List
nvme_mi_admin_get_log_supported_log_pages(2) β Retrieve nmve supported log pages
nvme_mi_admin_get_log_telemetry_ctrl(2) β Get Telemetry Controller-Initiated log page
nvme_mi_admin_get_log_telemetry_host(2) β Get Telemetry Host-Initiated log page
nvme_mi_admin_get_log_zns_changed_zones(2) β Retrieve list of zones that have changed
nvme_mi_admin_get_nsid_log(2) β Helper for Get Log Page functions
nvme_mi_admin_identify(2) β Perform an Admin identify command.
nvme_mi_admin_identify_active_ns_list(2) β Perform an Admin identify for an active namespace list
nvme_mi_admin_identify_allocated_ns(2) β Perform an Admin identify command for an allocated namespace
nvme_mi_admin_identify_allocated_ns_list(2) β Perform an Admin identify for an allocated namespace list
nvme_mi_admin_identify_cns_nsid(2) β Perform an Admin identify command using specific CNS/NSID parameters.
nvme_mi_admin_identify_ctrl(2) β Perform an Admin identify for a controller
nvme_mi_admin_identify_ctrl_list(2) β Perform an Admin identify for a controller list.
nvme_mi_admin_identify_ns(2) β Perform an Admin identify command for a namespace
nvme_mi_admin_identify_ns_descs(2) β Perform an Admin identify Namespace Identification Descriptor list command for a namespace
nvme_mi_admin_identify_nsid_ctrl_list(2) β Perform an Admin identify for a controller list with specific namespace ID
nvme_mi_admin_identify_partial(2) β Perform an Admin identify command, and retrieve partial response data.
nvme_mi_admin_identify_primary_ctrl(2) β Perform an Admin identify for primary controller capabilities data structure.
nvme_mi_admin_identify_secondary_ctrl_list(2) β Perform an Admin identify for a secondary controller list.
nvme_mi_admin_ns_attach(2) β Attach or detach namespace to controller(s)
nvme_mi_admin_ns_attach_ctrls(2) β Attach namespace to controllers
nvme_mi_admin_ns_detach_ctrls(2) β Detach namespace from controllers
nvme_mi_admin_req_hdr(2) β Admin command request header.
nvme_mi_admin_resp_hdr(2) β Admin command response header.
nvme_mi_admin_sanitize_nvm(2) β Start a subsystem Sanitize operation
nvme_mi_admin_security_recv(2) β Perform a Security Receive command on a controller.
nvme_mi_admin_security_send(2) β Perform a Security Send command on a controller.
nvme_mi_admin_set_features_power_mgmt(2) β Set power management feature
nvme_mi_admin_xfer(2) β Raw admin transfer interface.
nvme_mi_aem_aeei_get_aee(2) β return aee from aeei field
nvme_mi_aem_aeei_get_aeeid(2) β return aeeid from aeei field
nvme_mi_aem_aeei_set_aee(2) β set aee in the aeei field
nvme_mi_aem_aeei_set_aeeid(2) β set aeeid in the aeei field
nvme_mi_aem_aemti_get_aemgn(2) β return aemgn from aemti field
nvme_mi_aem_aeolli_get_aeoltl(2) β return aeoltl from aeolli field
nvme_mi_aem_aeolli_set_aeoltl(2) β set aeoltl in the aeolli field
nvme_mi_aem_aesi_get_aese(2) β return aese from aesi field
nvme_mi_aem_aesi_get_aesid(2) β return aesid from aesi field
nvme_mi_aem_aesi_set_aee(2) β set aee in the aesi field
nvme_mi_aem_aesi_set_aesid(2) β set aesid in the aesi field
nvme_mi_aem_config(2) β Provided for nvme_mi_aem_enable
nvme_mi_aem_disable(2) β Disable AE on the provided endpoint
nvme_mi_aem_enable(2) β Enable AE on the provided endpoint
nvme_mi_aem_enable_item(2) β AE Enabled item entry
nvme_mi_aem_enable_list(2) β AE enable list sent with SET CONFIG Asyncronous Event
nvme_mi_aem_enable_list_header(2) β AE Enable list header
nvme_mi_aem_get_enabled(2) β Return information on which AEs are enabled
nvme_mi_aem_get_fd(2) β Returns the pollable fd for AEM data available
nvme_mi_aem_get_next_event(2) β Get details for the next event to parse
nvme_mi_aem_handler_next_action(2) β Next action for the AEM state machine handler
nvme_mi_aem_msg(2) β AEM Message definition.
nvme_mi_aem_occ_data(2) β AEM Message definition.
nvme_mi_aem_occ_list_hdr(2) β AE occurrence list header
nvme_mi_aem_open(2) β Prepare an existing endpoint to receive AEMs
nvme_mi_aem_process(2) β Process AEM on the provided endpoint
nvme_mi_aem_supported_item(2) β AE Supported List Item
nvme_mi_aem_supported_list(2) β AE Supported List received with GET CONFIG Asynchronous Event
nvme_mi_aem_supported_list_header(2) β Asynchronous Event Supported List Header.
nvme_mi_ccs(2) β Get State Control Primitive Success Response Fields - Control Primitive Specific Response
nvme_mi_close(2) β Close an endpoint connection and release resources, including controller objects.
nvme_mi_close_ctrl(2) β free a controller
nvme_mi_cmd_supported_effects(2) β MI Command Supported and Effects Data Structure
nvme_mi_cmd_supported_effects_log(2) β NVMe-MI Commands Supported and Effects Log
nvme_mi_config_id(2) β NVMe-MI Configuration identifier.
nvme_mi_config_smbus_freq(2) β SMBus/I2C frequency values
nvme_mi_control(2) β Perform a Control Primitive command
nvme_mi_control_opcode(2) β Operation code for Control Primitives.
nvme_mi_control_req(2) β The Control Primitive request.
nvme_mi_create_root(2) β Create top-level MI (root) handle.
nvme_mi_csts(2) β Controller Health Data Structure (CHDS) - Controller Status (CSTS)
nvme_mi_ctrl_health_status(2) β Controller Health Data Structure (CHDS)
nvme_mi_ctrl_id(2) β get the ID of a controller
nvme_mi_cwarn(2) β Controller Health Data Structure (CHDS) - Critical Warning (CWARN)
nvme_mi_dtyp(2) β Data Structure Type field.
nvme_mi_elem(2) β Element Descriptor Types
nvme_mi_event(2) β AE event information structure
nvme_mi_free_root(2) β Free root object.
nvme_mi_init_ctrl(2) β initialise a NVMe controller.
nvme_mi_message_type(2) β NVMe-MI message type field.
nvme_mi_mi_opcode(2) β Operation code for supported NVMe-MI commands.
nvme_mi_mi_read_mi_data_ctrl(2) β Perform a Read MI Data Structure command, retrieving controller information
nvme_mi_mi_read_mi_data_ctrl_list(2) β Perform a Read MI Data Structure command, retrieving the list of attached controllers.
nvme_mi_mi_read_mi_data_port(2) β Perform a Read MI Data Structure command, retrieving port data.
nvme_mi_mi_read_mi_data_subsys(2) β Perform a Read MI Data Structure command, retrieving subsystem data.
nvme_mi_mi_req_hdr(2) β MI request message header.
nvme_mi_mi_resp_hdr(2) β MI response message header.
nvme_mi_mi_subsystem_health_status_poll(2) β Read the Subsystem Health Data Structure from the NVM subsystem
nvme_mi_mi_xfer(2) β Raw mi transfer interface.
nvme_mi_msg_hdr(2) β General MI message header.
nvme_mi_msg_resp(2) β Generic response type.
nvme_mi_nvm_ss_health_status(2) β Subsystem Management Data Structure
nvme_mi_open_mctp(2) β Create an endpoint using a MCTP connection.
nvme_mi_osc(2) β Optionally Supported Command Data Structure
nvme_mi_port_pcie(2) β PCIe Port Specific Data
nvme_mi_port_smb(2) β SMBus Port Specific Data
nvme_mi_read_ctrl_info(2) β Controller Information Data Structure
nvme_mi_read_nvm_ss_info(2) β NVM Subsystem Information Data Structure
nvme_mi_read_port_info(2) β Port Information Data Structure
nvme_mi_read_sc_list(2) β Management Endpoint Buffer Supported Command List Data Structure
nvme_mi_resp_status(2) β values for the response status field
nvme_mi_set_probe_enabled(2) β enable/disable the probe for new endpoints
nvme_mi_status_to_string(2) β return a string representation of the MI status.
nvme_mi_vpd_hdr(2) β Vital Product Data Common Header
nvme_mi_vpd_mr_common(2) β NVMe MultiRecord Area
nvme_mi_vpd_mra(2) β NVMe MultiRecord Area
nvme_mi_vpd_ppmra(2) β NVMe PCIe Port MultiRecord Area
nvme_mi_vpd_telem(2) β Vital Product Data Element Descriptor
nvme_mi_vpd_tra(2) β Vital Product Data Topology MultiRecord
nvme_namespace_attach_ctrls(2) β Attach namespace to controller(s)
nvme_namespace_detach_ctrls(2) β Detach namespace from controller(s)
nvme_namespace_filter(2) β Filter for namespaces
nvme_namespace_first_path(2) β Start path iterator
nvme_namespace_for_each_path(2) β Traverse paths
nvme_namespace_for_each_path_safe(2) β Traverse paths
nvme_namespace_next_path(2) β Next path iterator
nvme_nbft_free(2) β Free the struct nbft_info and its contents
nvme_nbft_read(2) β Read and parse contents of an ACPI NBFT table
nvme_nd_ns_fpi(2) β If a format operation is in progress, this field indicates the percentage of the namespace that remains to be formatted.
nvme_next_host(2) β Next host iterator
nvme_next_subsystem(2) β Next subsystem iterator
nvme_ns_attach(2) β Attach or detach namespace to controller(s)
nvme_ns_attach_args(2) β Arguments for Nvme Namespace Management command
nvme_ns_attach_ctrls(2) β Attach namespace to controllers
nvme_ns_attach_sel(2) β Namespace Attachment - Select
nvme_ns_compare(2) β Compare data on a namespace
nvme_ns_detach_ctrls(2) β Detach namespace from controllers
nvme_ns_flush(2) β Flush data to a namespace
nvme_ns_get_csi(2) β Command set identifier of a namespace
nvme_ns_get_ctrl(2) β &nvme_ctrl_t of a namespace
nvme_ns_get_eui64(2) β 64-bit eui of a namespace
nvme_ns_get_fd(2) β Get associated file descriptor
nvme_ns_get_firmware(2) β Firmware string of a namespace
nvme_ns_get_generic_name(2) β Returns name of generic namespace chardev.
nvme_ns_get_lba_count(2) β LBA count of a namespace
nvme_ns_get_lba_size(2) β LBA size of a namespace
nvme_ns_get_lba_util(2) β LBA utilization of a namespace
nvme_ns_get_meta_size(2) β Metadata size of a namespace
nvme_ns_get_model(2) β Model of a namespace
nvme_ns_get_name(2) β sysfs name of a namespace
nvme_ns_get_nguid(2) β 128-bit nguid of a namespace
nvme_ns_get_nsid(2) β NSID of a namespace
nvme_ns_get_serial(2) β Serial number of a namespace
nvme_ns_get_subsystem(2) β &nvme_subsystem_t of a namespace
nvme_ns_get_sysfs_dir(2) β sysfs directory of a namespace
nvme_ns_get_uuid(2) β UUID of a namespace
nvme_ns_head_get_sysfs_dir(2) β sysfs dir of namespave head
nvme_ns_id_desc(2) β Namespace identifier type descriptor
nvme_ns_id_desc_nidt(2) β Known namespace identifier types
nvme_ns_identify(2) β Issue an 'identify namespace' command
nvme_ns_identify_descs(2) β Issue an 'identify descriptors' command
nvme_ns_list(2) β Namespace List
nvme_ns_metadata_type(2) β Namespace Metadata Element Types
nvme_ns_mgmt(2) β Issue a Namespace management command
nvme_ns_mgmt_args(2) β Arguments for NVMe Namespace Management command
nvme_ns_mgmt_create(2) β Create a non attached namespace
nvme_ns_mgmt_delete(2) β Delete a non attached namespace
nvme_ns_mgmt_delete_timeout(2) β Delete a non attached namespace with timeout
nvme_ns_mgmt_host_sw_specified(2) β Namespace management Host Software Specified Fields.
nvme_ns_mgmt_sel(2) β Namespace Management - Select
nvme_ns_read(2) β Read from a namespace
nvme_ns_release_fd(2) β Close fd and clear fd from ns object
nvme_ns_rescan(2) β Initiate a controller rescan
nvme_ns_verify(2) β Verify data on a namespace
nvme_ns_write(2) β Write to a namespace
nvme_ns_write_protect_cfg(2) β Write Protection - Write Protection State
nvme_ns_write_uncorrectable(2) β Issus a 'write uncorrectable' command
nvme_ns_write_zeros(2) β Write zeros to a namespace
nvme_nss_hw_err_event(2) β NVM Subsystem Hardware Error Event
nvme_nvm_id_ns(2) β NVME Command Set I/O Command Set Specific Identify Namespace Data Structure
nvme_nvm_id_ns_elbaf(2) β This field indicates the extended LBA format
nvme_nvm_id_ns_pif(2) β This field indicates the type of the Protection Information Format
nvme_nvm_identify_ctrl(2) β Identify controller data
nvme_nvmeset_pl_status(2) β Predictable Latency Per NVM Set Log - Status
nvme_nvmset_attr(2) β NVM Set Attributes Entry
nvme_nvmset_pl_events(2) β Predictable Latency Per NVM Set Log - Event Type
nvme_nvmset_predictable_lat_log(2) β Predictable Latency Mode - Deterministic Threshold Configuration Data
nvme_open(2) β Open an nvme controller or namespace device
nvme_parse_uri(2) β Parse the URI string
nvme_passthru_cmd(2) β nvme passthrough command structure
nvme_passthru_cmd64(2) β 64-bit nvme passthrough command structure
nvme_path_get_ana_state(2) β ANA state of an nvme_path_t object
nvme_path_get_ctrl(2) β Parent controller of an nvme_path_t object
nvme_path_get_name(2) β sysfs name of an &nvme_path_t object
nvme_path_get_ns(2) β Parent namespace of an nvme_path_t object
nvme_path_get_numa_nodes(2) β NUMA nodes of an nvme_path_t object
nvme_path_get_queue_depth(2) β Queue depth of an nvme_path_t object
nvme_path_get_sysfs_dir(2) β sysfs directory of an nvme_path_t object
nvme_paths_filter(2) β Filter for paths
nvme_pel_ehai(2) β This field indicates the persistent event header additional information
nvme_pel_ehai_pit(2) β Persistent Event Header Additional Information - Port Identifier Type
nvme_pel_rci(2) β This field indicates the persistent event log reporting context
nvme_pel_rci_rcpit(2) β Persistent Event Log Reporting Context - Port Identifier Type
nvme_perf_attr_id(2) β Performance attribute identifier structure
nvme_perf_attr_id_list(2) β Performance attribute identifier list structure
nvme_perf_characteristics(2) β Performance attribute structure
nvme_persistent_event_entry(2) β Persistent Event
nvme_persistent_event_log(2) β Persistent Event Log
nvme_persistent_event_types(2) β Persistent event log events
nvme_pevent_log_action(2) β Persistent Event Log - Action
nvme_phy_rx_eom_log(2) β Physical Interface Receiver Eye Opening Measurement Log
nvme_phy_rx_eom_progress(2) β EOM In Progress Values
nvme_plm_config(2) β Predictable Latency Mode - Deterministic Threshold Configuration Data Structure
nvme_pmr_size(2) β Calculate size of persistent memory region elasticity buffer
nvme_pmr_throughput(2) β Calculate throughput of persistent memory buffer
nvme_pmrcap(2) β This field indicates the persistent memory region capabilities
nvme_pmrctl(2) β This field indicates the persistent memory region control
nvme_pmrebs(2) β This field indicates the persistent memory region elasticity buffer size
nvme_pmrmsc(2) β This field indicates the persistent memory region memory space control
nvme_pmrsts(2) β This field indicates the persistent memory region status
nvme_pmrswtp(2) β This field indicates the persistent memory region sustained write throughput
nvme_power_on_reset_info_list(2) β Controller Reset Information
nvme_primary_ctrl_cap(2) β Identify - Controller Capabilities Structure
nvme_psd_flags(2) β Possible flag values in nvme power state descriptor
nvme_psd_power_scale(2) β power scale occupies the upper 3 bits
nvme_psd_ps(2) β Known values for &struct nvme_psd %ips and %aps. Use with nvme_psd_power_scale() to extract the power scale field to match this enum.
nvme_psd_workload(2) β Specifies a workload hint in the Power Management Feature (see &struct nvme_psd.apw) to inform the NVM subsystem or indicate the conditions for the active power level.
nvme_pull_model_ddc_req_log(2) β Pull Model DDC Request Log
nvme_reachability_association_desc(2) β Reachability Association Descriptor
nvme_reachability_associations_log(2) β Reachability Associations Log
nvme_reachability_group_desc(2) β Reachability Group Descriptor
nvme_reachability_groups_log(2) β Reachability Groups Log
nvme_read(2) β Submit an nvme user read command
nvme_read_config(2) β Read NVMe JSON configuration file
nvme_read_key(2) β Read key raw data
nvme_refresh_topology(2) β Refresh nvme_root_t object contents
nvme_register_offsets(2) β controller registers for all transports. This is the layout of BAR0/1 for PCIe, and properties for fabrics.
nvme_registered_ctrl(2) β Registered Controller Data Structure
nvme_registered_ctrl_ext(2) β Registered Controller Extended Data Structure
nvme_rescan_ctrl(2) β Rescan an existing controller
nvme_resv_acquire(2) β Send an nvme reservation acquire
nvme_resv_acquire_args(2) β Arguments for the NVMe Reservation Acquire Command
nvme_resv_cptpl(2) β Reservation Register - Change Persist Through Power Loss State
nvme_resv_notification_log(2) β Reservation Notification Log
nvme_resv_notify_rnlpt(2) β Reservation Notification Log - Reservation Notification Log Page Type
nvme_resv_racqa(2) β Reservation Acquire - Reservation Acquire Action
nvme_resv_register(2) β Send an nvme reservation register
nvme_resv_register_args(2) β Arguments for the NVMe Reservation Register command
nvme_resv_release(2) β Send an nvme reservation release
nvme_resv_release_args(2) β Arguments for the NVMe Reservation Release Command
nvme_resv_report(2) β Send an nvme reservation report
nvme_resv_report_args(2) β Arguments for the NVMe Reservation Report command
nvme_resv_rrega(2) β Reservation Register - Reservation Register Action
nvme_resv_rrela(2) β Reservation Release - Reservation Release Action
nvme_resv_rtype(2) β Reservation Type Encoding
nvme_resv_status(2) β Reservation Status Data Structure
nvme_revoke_tls_key(2) β Revoke TLS key from keyring
nvme_rotational_media_info_log(2) β Rotational Media Information Log
nvme_sanitize_compln_event(2) β Sanitize Completion Event Data
nvme_sanitize_log_page(2) β Sanitize Status (Log Identifier 81h)
nvme_sanitize_nvm(2) β Start a sanitize operation
nvme_sanitize_nvm_args(2) β Arguments for the NVMe Sanitize NVM command
nvme_sanitize_sanact(2) β Sanitize Action
nvme_sanitize_ssi(2) β Sanitize State Information (SSI)
nvme_sanitize_sstat(2) β Sanitize Status (SSTAT)
nvme_sanitize_start_event(2) β Sanitize Start Event Data
nvme_scan(2) β Scan NVMe topology
nvme_scan_ctrl(2) β Scan on a controller
nvme_scan_ctrl_namespace_paths(2) β Scan for namespace paths in a controller
nvme_scan_ctrl_namespaces(2) β Scan for namespaces in a controller
nvme_scan_ctrls(2) β Scan for controllers
nvme_scan_namespace(2) β scan namespace based on sysfs name
nvme_scan_ns_head_paths(2) β Scan for namespace paths
nvme_scan_subsystem_namespaces(2) β Scan for namespaces in a subsystem
nvme_scan_subsystems(2) β Scan for subsystems
nvme_scan_tls_keys(2) β Iterate over TLS keys in a keyring
nvme_scan_topology(2) β Scan NVMe topology and apply filter
nvme_secondary_ctrl(2) β Secondary Controller Entry
nvme_secondary_ctrl_list(2) β Secondary Controller List
nvme_security_receive(2) β Security Receive command
nvme_security_receive_args(2) β Arguments for the NVMe Security Receive command
nvme_security_send(2) β Security Send command
nvme_security_send_args(2) β Arguments for the NVMe Security Send command
nvme_self_test_log(2) β Device Self-test (Log Identifier 06h)
nvme_set_etdas(2) β Set the Extended Telemetry Data Area 4 Supported bit
nvme_set_feat_event_layout(2) β This field indicates the set feature event layout
nvme_set_feature_event(2) β Set Feature Event Data
nvme_set_features(2) β Set a feature attribute
nvme_set_features_arbitration(2) β Set arbitration features
nvme_set_features_args(2) β Arguments for the NVMe Admin Set Feature command
nvme_set_features_async_event(2) β Set asynchronous event feature
nvme_set_features_auto_pst(2) β Set autonomous power state feature
nvme_set_features_data(2) β Helper function for @nvme_set_features()
nvme_set_features_endurance_evt_cfg(2) β Set endurance event config feature
nvme_set_features_err_recovery(2) β Set error recovery feature
nvme_set_features_hctm(2) β Set thermal management feature
nvme_set_features_host_behavior(2) β Set host behavior feature
nvme_set_features_host_id(2) β Set enable extended host identifiers feature
nvme_set_features_iocs_profile(2) β Set I/O command set profile feature
nvme_set_features_irq_coalesce(2) β Set IRQ coalesce feature
nvme_set_features_irq_config(2) β Set IRQ config feature
nvme_set_features_lba_range(2) β Set LBA range feature
nvme_set_features_lba_sts_interval(2) β Set LBA status information feature
nvme_set_features_nopsc(2) β Set non-operational power state feature
nvme_set_features_plm_config(2) β Set predictable latency feature
nvme_set_features_plm_window(2) β Set window select feature
nvme_set_features_power_mgmt(2) β Set power management feature
nvme_set_features_resv_mask(2) β Set reservation notification mask feature
nvme_set_features_resv_mask2(2) β Set reservation notification mask feature
nvme_set_features_resv_persist(2) β Set persist through power loss feature
nvme_set_features_resv_persist2(2) β Set persist through power loss feature
nvme_set_features_rrl(2) β Set read recovery level feature
nvme_set_features_sanitize(2) β Set sanitize feature
nvme_set_features_simple(2) β Helper function for @nvme_set_features()
nvme_set_features_sw_progress(2) β Set pre-boot software load count feature
nvme_set_features_temp_thresh(2) β Set temperature threshold feature
nvme_set_features_temp_thresh2(2) β Set temperature threshold feature
nvme_set_features_timestamp(2) β Set timestamp feature
nvme_set_features_volatile_wc(2) β Set volatile write cache feature
nvme_set_features_write_atomic(2) β Set write atomic feature
nvme_set_features_write_protect(2) β Set write protect feature
nvme_set_features_write_protect2(2) β Set write protect feature
nvme_set_keyring(2) β Link keyring for lookup
nvme_set_property(2) β Set controller property
nvme_set_property_args(2) β Arguments for NVMe Set Property command
nvme_set_root(2) β Set nvme_root_t context
nvme_smart_crit(2) β Critical Warning
nvme_smart_egcw(2) β Endurance Group Critical Warning Summary
nvme_smart_log(2) β SMART / Health Information Log (Log Identifier 02h)
nvme_st_code(2) β Self-test Code value
nvme_st_curr_op(2) β Current Device Self-Test Operation
nvme_st_result(2) β Self-test Result
nvme_st_valid_diag_info(2) β Valid Diagnostic Information
nvme_status_code(2) β Returns the NVMe Status Code
nvme_status_code_type(2) β Returns the NVMe Status Code Type
nvme_status_equals(2) β helper to check a status against a type and value
nvme_status_field(2) β Defines all parts of the nvme status field: status code, status code type, and additional flags.
nvme_status_get_type(2) β extract the type from a nvme_* return value
nvme_status_get_value(2) β extract the status value from a nvme_* return value
nvme_status_result(2) β Result of the device self-test operation
nvme_status_to_errno(2) β Converts nvme return status to errno
nvme_status_to_string(2) β Returns string describing nvme return status.
nvme_status_type(2) β type encoding for NVMe return values, when represented as an int.
nvme_std_perf_attr(2) β Standard performance attribute structure
nvme_streams_directive_params(2) β Streams Directive - Return Parameters Data Structure
nvme_streams_directive_status(2) β Streams Directive - Get Status Data Structure
nvme_submit_admin_passthru(2) β Submit an nvme passthrough admin command
nvme_submit_admin_passthru64(2) β Submit a 64-bit nvme passthrough admin command
nvme_submit_io_passthru(2) β Submit an nvme passthrough command
nvme_submit_io_passthru64(2) β Submit a 64-bit nvme passthrough command
nvme_subsys_filter(2) β Filter for subsystems
nvme_subsys_type(2) β Type of the NVM subsystem.
nvme_subsystem_first_ctrl(2) β First ctrl iterator
nvme_subsystem_first_ns(2) β Start namespace iterator
nvme_subsystem_for_each_ctrl(2) β Traverse controllers
nvme_subsystem_for_each_ctrl_safe(2) β Traverse controllers
nvme_subsystem_for_each_ns(2) β Traverse namespaces
nvme_subsystem_for_each_ns_safe(2) β Traverse namespaces
nvme_subsystem_get_application(2) β Return the application string
nvme_subsystem_get_fw_rev(2) β Return the firmware rev of subsystem
nvme_subsystem_get_host(2) β Returns nvme_host_t object
nvme_subsystem_get_iopolicy(2) β Return the IO policy of subsytem
nvme_subsystem_get_model(2) β Return the model of subsystem
nvme_subsystem_get_name(2) β sysfs name of an nvme_subsystem_t object
nvme_subsystem_get_nqn(2) β Retrieve NQN from subsystem
nvme_subsystem_get_serial(2) β Return the serial number of subsystem
nvme_subsystem_get_sysfs_dir(2) β sysfs directory of an nvme_subsystem_t object
nvme_subsystem_get_type(2) β Returns the type of a subsystem
nvme_subsystem_lookup_namespace(2) β lookup namespace by NSID
nvme_subsystem_next_ctrl(2) β Next ctrl iterator
nvme_subsystem_next_ns(2) β Next namespace iterator
nvme_subsystem_release_fds(2) β Close all opened fds under subsystem
nvme_subsystem_reset(2) β Initiate a subsystem reset
nvme_subsystem_set_application(2) β Set the application string
nvme_supported_cap_config_list_log(2) β Supported Capacity Configuration list log page
nvme_supported_log_pages(2) β Supported Log Pages - Log
nvme_telemetry_da(2) β Telemetry Log Data Area
nvme_telemetry_log(2) β Retrieve internal data specific to the manufacturer.
nvme_thermal_exc_event(2) β Thermal Excursion Event Data
nvme_time_stamp_change_event(2) β Timestamp Change Event
nvme_timestamp(2) β Timestamp - Data Structure for Get Features
nvme_unit(2) β Defined buffer size and write throughput granularity units
nvme_unlink_ctrl(2) β Unlink controller
nvme_update_config(2) β Update JSON configuration
nvme_update_key(2) β Update key raw data
nvme_uring_cmd(2) β nvme uring command structure
nvme_verify(2) β Send an nvme verify command
nvme_version(2) β Selector for version to be returned by @nvme_get_version
nvme_virt_mgmt_act(2) β Virtualization Management - Action
nvme_virt_mgmt_rt(2) β Virtualization Management - Resource Type
nvme_virtual_mgmt(2) β Virtualization resource management
nvme_virtual_mgmt_args(2) β Arguments for the NVMe Virtualization resource management command
nvme_vs(2) β This field indicates the version
nvme_vs_perf_attr(2) β Vendor specific performance attribute structure
nvme_write(2) β Submit an nvme user write command
nvme_write_uncorrectable(2) β Submit an nvme write uncorrectable command
nvme_write_zeros(2) β Submit an nvme write zeroes command
nvme_zns_append(2) β Append data to a zone
nvme_zns_append_args(2) β Arguments for the NVMe ZNS Append command
nvme_zns_changed_zone_log(2) β ZNS Changed Zone List log
nvme_zns_desc(2) β Zone Descriptor Data Structure
nvme_zns_id_ctrl(2) β I/O Command Set Specific Identify Controller Data Structure for the Zoned Namespace Command Set
nvme_zns_id_ns(2) β Zoned Namespace Command Set Specific Identify Namespace Data Structure
nvme_zns_identify_ctrl(2) β ZNS identify controller data
nvme_zns_identify_ns(2) β ZNS identify namespace data
nvme_zns_lbafe(2) β LBA Format Extension Data Structure
nvme_zns_mgmt_recv(2) β ZNS management receive command
nvme_zns_mgmt_recv_args(2) β Arguments for the NVMe ZNS Management Receive command
nvme_zns_mgmt_send(2) β ZNS management send command
nvme_zns_mgmt_send_args(2) β Arguments for the NVMe ZNS Management Send command
nvme_zns_recv_action(2) β Zone Management Receive - Zone Receive Action Specific Features
nvme_zns_report_options(2) β Zone Management Receive - Zone Receive Action Specific Field
nvme_zns_report_zones(2) β Return the list of zones
nvme_zns_send_action(2) β Zone Management Send - Zone Send Action
nvme_zns_za(2) β Zone Descriptor Data Structure
nvme_zns_zs(2) β Zone Descriptor Data Structure - Zone State
nvme_zns_zt(2) β Zone Descriptor Data Structure - Zone Type
nvme_zone_report(2) β Report Zones Data Structure
nvmf_add_ctrl(2) β Connect a controller and update topology
nvmf_addr_family(2) β Address Family codes for Discovery Log Page entry ADRFAM field
nvmf_adrfam_str(2) β Decode ADRFAM field
nvmf_cms_str(2) β Decode RDMA connection management service field
nvmf_connect_ctrl(2) β Connect a controller
nvmf_connect_data(2) β Data payload for the 'connect' command
nvmf_connect_disc_entry(2) β Connect controller based on the discovery log page entry
nvmf_default_config(2) β Default values for fabrics configuration
nvmf_dim_data(2) β Discovery Information Management (DIM) - Data
nvmf_dim_entfmt(2) β Discovery Information Management Entry Format
nvmf_dim_etype(2) β Discovery Information Management Entity Type
nvmf_dim_tas(2) β Discovery Information Management Task
nvmf_disc_eflags(2) β Discovery Log Page entry flags.
nvmf_disc_log_entry(2) β Discovery Log Page entry
nvmf_discovery_log(2) β Discovery Log Page (Log Identifier 70h)
nvmf_eflags_str(2) β Decode EFLAGS field
nvmf_exat_len(2) β Return length rounded up by 4
nvmf_exattype(2) β Extended Attribute Type
nvmf_ext_attr(2) β Extended Attribute (EXAT)
nvmf_ext_die(2) β Extended Discovery Information Entry (DIE)
nvmf_get_discovery_log(2) β Return the discovery log page
nvmf_get_discovery_wargs(2) β Get the discovery log page with args
nvmf_hostid_from_file(2) β Reads the host identifier from the config default location
nvmf_hostid_generate(2) β Generate a machine specific host identifier
nvmf_hostnqn_from_file(2) β Reads the host nvm qualified name from the config default location
nvmf_hostnqn_generate(2) β Generate a machine specific host nqn
nvmf_hostnqn_generate_from_hostid(2) β Generate a host nqn from host identifier
nvmf_log_discovery_lid_support(2) β Discovery log specific support
nvmf_log_discovery_lsp(2) β Discovery log specific field
nvmf_prtype_str(2) β Decode RDMA Provider type field
nvmf_qptype_str(2) β Decode RDMA QP Service type field
nvmf_rdma_cms(2) β RDMA Connection Management Service Type codes for Discovery Log Page entry TSAS RDMA_CMS field
nvmf_rdma_prtype(2) β RDMA Provider Type codes for Discovery Log Page entry TSAS RDMA_PRTYPE field
nvmf_rdma_qptype(2) β RDMA QP Service Type codes for Discovery Log Page entry TSAS RDMA_QPTYPE field
nvmf_register_ctrl(2) β Perform registration task with a DC
nvmf_sectype_str(2) β Decode SECTYPE field
nvmf_subtype_str(2) β Decode SUBTYPE field
nvmf_tcp_sectype(2) β Transport Specific Address Subtype Definition for NVMe/TCP Transport
nvmf_treq(2) β Transport Requirements codes for Discovery Log Page entry TREQ field
nvmf_treq_str(2) β Decode TREQ field
nvmf_trtype(2) β Transport Type codes for Discovery Log Page entry TRTYPE field
nvmf_trtype_str(2) β Decode TRTYPE field
nvmf_update_config(2) β Update fabrics configuration values